products
Downloads
Perdure High Build Coating System
Perdure High Build Coating System | (industrial wear surface) ~ 20-25mil thickness
Perdüre High Build Coating System is a very important system which is used for both office and residential areas. It helps to improve the aesthetics of the house, provide slip resistance and make them durable and easy to clean. It is applied at 20-25 mil thickness. This product has been used for many years all over America and Canada. A primer is usually applied first and then 2 layers/coats.
- Where it is commonly used
- Warehouses and storage areas
- Garage floors
- Laundry areas
- Correctional facilities
- Showers
- Utilities
Procedure
- Apply one coat of Perdure E02, 100% solids epoxy primer
- Apply one coat of Perdure E20, 100% solids epoxy body coat
- Apply second coat of Perdure E20, 100% epoxy body coat
- Select one of the top coats- Perdure U50, Perdure U90 or Perdure U45
Application should be done evenly to ensure maximum result.
Perdure Traffic Coating Systems ~ 40-60 mil thickness
Perdure Traffic Coating Systems | ~ 40-60 mil thickness
Perdüre high build traffic coating system is a product that has been used in Canada and United States to take care of the floors. It is usually applied at 40-50 mil thickness to help improve the look and feel of the floor, improve slip resistance and help ensure durability of the floor. It also helps to ensure easier cleaning of the floor. It is usually applied in two layers over a primer.
Where it is used
- Airport hangers
- Cafeterias
- Clean rooms
- Correctional facilities
- Laundries
- Locker rooms
- Light manufacturing
- Warehouses among others
How it is applied
- Apply one coat of Perdure EO2, 100% solids epoxy primer
- Apply one coat of Perdure E10, 100% solids epoxy binder with self-leveling filler
- Apply a coat of Perdure E20, 100% solids epoxy body coat
- Select any one of these top coats- Perdure U50, Perdure U90 or Perdure U45
Technical Data
Flammability, ASTM D-635 | Self Extinguishing | Fungus & Bacteria Growth, MIL-F-52505 | Will not support growth of fungus or bacteria when subjected to mildew and bacteria tests |
Hardness, ASTM D-2240 | 80-84D | Bond Strength to Concrete, ACI 403 | 250psi (100% concrete failure) |
Resistance to Elevated Temperature, MIL D 3134f | n/a | Coefficient of Friction, ASTM D 2047 | 0.80-0.85 |
Water Absorption, ASTM D570 | Nil | Thermal Shock Resistance, ASTM C 884 | Passes |
Abrasion Resistance, ASM C501 | 50mg | Impact Resistance, MIL D3134F | Will chip with concrete |
Compressive Strength, ASTM C579. 7 days | n/a | Tensile Strength, ASTM C307 | n/a |
Thermal coefficient of Expansion, ASTM C531 | n/a |